Spanish English Chinese

1. The Introduction of Reverse Osmosis Chemicals

The reverse osmosis chemical, IRASD-200 is a highly effective scale inhibitor developed for reverse osmosis (RO) systems.

During the water treatment, dirt and iron scale are formed on the reverse osmosis membrane. They can degrade the performance of the water treatment system. Contaminants and deposits that accumulate on the reverse osmosis membrane will cause deterioration in permeability. Frequent downtime, increased water consumption and increased energy consumption. This requires the reverse osmosis membrane to be replaced in advance.

IRASD-200 is a high-efficiency reverse osmosis antiscalant containing a dispersant. It is easy to use. This reverse osmosis chemical is formulated with an alkaline cleaning solution. Designed to remove organic and biofouling from reverse osmosis membranes and ultrafiltration membranes. IRASD-200 is used in a wide range of applications and can be used in combination with a wide range of other cleaning agents.

During the water treatment process, the reverse osmosis membrane gradually forms a scale. This leads to a significant drop in system efficiency. The precipitate builds upon the membrane. As a result, the permeate water flow rate and the salt rejection rate decrease. Fouling can result in deterioration of water quality, reduced production, unplanned downtime, and early replacement of membrane modules.

Regular maintenance and cleaning programs maintain low pump output pressure. And can extend the life of the membrane. Return on investment (ROI) is as high as 100% to 250%. Compared with the initial baseline data, the standard permeates water yield and desalination rate decreased by 10%-15%. The membrane module should be cleaned at this time.

The length of the cleaning cycle depends on the amount and nature of the scale. It usually takes 3-5 hours. However, in the case of serious fouling, it is necessary to immerse the membrane for a few minutes before recycling. This can better remove serious fouling. For membranes that are heavily fouled, it may be necessary to repeat this cleaning cycle.

After completing the cleaning procedure, it is recommended to rinse the membrane with premium water immediately. To remove residual IRASD-200. When the membrane is reused in the factory, the 15-20 minutes of produced water that was initially discharged must be discharged. Or determine the length of time according to the actual situation, to ensure that it does not contain any cleaning fluid.

reverse osmosis chemicals plant

2. RO Chemicals Plant

Shandong IRO Water Treatment Co., Ltd. is committed to the production and research and development of water treatment agent series products. The main products include organophosphorus, polymers, bactericides, RO chemicals, and other related water treatment chemicals.

Since its inception in 2002, the current annual production capacity of IRO Water has reached 45,000 MT, including 10,000 MT HEDP, 8000 MT PBTC and 15,000 MT acrylic polymer (such as polyacrylic acid, sodium polyacrylate, etc.).

“Implementing large-scale industrial production of fine chemicals” is the business philosophy of IRO. Shandong IRO Water Treatment is committed to achieving both high-quality and low-quality production of scale effects.

We have a group of senior management personnel and experienced and highly skilled professional and technical personnel. IRO has always focused on technological innovation and research and development. Establish close relations with well-known research institutes and institutions such as Shandong University, Qingdao University of Science and Technology, and the Xi’an University of Technology. Resource sharing, cooperation and win-win.

If you have any business related to environmental protection projects, sewage treatment, please contact Shandong IRO Water Treatment. Reliable, professional, and trustworthy.

Leave a Reply

Your email address will not be published. Required fields are marked *

11Mar 2020

Abstract: Computational chemists have actually produced a unique, synthetic, three-stranded particle that operates just like a natural metalloenzyme, or an enzyme which contains metal ions. Enzymes are nature’s powerhouses. Discovered in the cells of all animals, plants, as well as every other living microorganism, they accelerate the chain reactions that activate countless organic functions– from […]

01Nov 2019

Abstract: Maleic anhydride is used as raw material, sodium tungstate is used as catalyst, hydrogen peroxide is used as a cyclizing agent and Ca(OH)2 is used as an initiator. Polyepoxysuccinic acid (PESA) water treatment chemical was prepared by aqueous solution polymerization. PESA is a green, highly effective scale inhibitor. The optimal synthesis conditions were determined […]

31Oct 2019

Benzotriazole Corrosion Inhibitor Analysis in the Action Mechanism Abstract: This post introduces the properties and mechanism of benzotriazole corrosion inhibitors. The synergistic action of benzotriazole and imidazole better illustrates the progress of the sustained release. Combined with the corrosion example of copper in sodium chloride solution to illustrate the corrosion inhibition of triazole compounds. Keywords: […]

17Sep 2019

Abstract: A water-soluble copolymer scale inhibitor was synthesized from acrylic acid (AA) and 2-acryloyl-2-methyl propane sulfonic acid (AMPS). The scale inhibition and dispersion properties of the copolymer were determined. The effects of monomer ratio, reaction temperature and molecular weight modifier on the scale inhibition performance of the copolymer were investigated. Keywords: sulfonic acid, copolymer, scale […]

09Sep 2019

This article describes the commonly used experimental methods for assessing the biodegradability of polyacrylic acid polymers. It is recommended to use the carbon dioxide (PCD), oxygen consumption (COD) and infrared spectroscopy images of biodegradation to comprehensively analyze the biodegradability of polyacrylic acid polymers. The volume of the bioreactor is 2L, the concentration of the tested […]

23Aug 2019

2-Hydroxyphosphonoacetic acid is a good scale inhibitor. Its appearance is a dark brown liquid with a molecular formula of C2H5O6P and a relative molecular mass of 156.03. The preparation method generally has the following three methods. Method One 16.3 parts (0.11 mol/L) 50% aqueous solution of dihydroxyacetic acid (hydrated glyoxylic acid) and 8.2 parts (0.1 […]

30Jul 2019

Through the static scale inhibition test, we studied the scale inhibition performance of PBTC and HEDP on calcium carbonate scale under low-temperature conditions (2°C-15°C). The results show that the scale inhibition performance of PBTC and HEDP on calcium carbonate scale is good at 2°C-15°C. The initial calcium ion + alkalinity has a great influence on […]

27Jun 2019

The full name of DBNPA is 2-2-dibromo-3-nitriloproion amide. It is a broad-spectrum and efficient industrial fungicide. DBNPA is used to prevent bacteria and algae from growing in papermaking, industrial circulating cooling water, mechanical lubricants, pulp, wood, paint, and plywood. 2-2-Dibromo-3-Nitrilopropionamide (DBNPA) is currently popular at home and abroad. Organic bromine fungicides. Sterilization mechanism of DBNPA […]

26Jun 2019

1. The Introduction of Reverse Osmosis Chemicals The reverse osmosis chemical, IRASD-200 is a highly effective scale inhibitor developed for reverse osmosis (RO) systems. During the water treatment, dirt and iron scale are formed on the reverse osmosis membrane. They can degrade the performance of the water treatment system. Contaminants and deposits that accumulate on […]

25Jun 2019

2-mercaptobenzothiazole (MBT) is an important variety of thiazole rubber vulcanization accelerators. At the same time, it is also an important auxiliary agent for oxidation and corrosion resistance. 2-MBT is a pale yellow powder or granule. It has an unpleasant smell. The melting point is above 173.0°C. The relative density is 1.41 to 1.48. 2-mercaptobenzothiazole is […]